Sunday, October 30, 2011

Kidde 900-0113-02 Carbon Monoxide and Explosive Gas Alarm

!±8±Kidde 900-0113-02 Carbon Monoxide and Explosive Gas Alarm

Brand : Kidde
Rate :
Price : $69.00
Post Date : Oct 30, 2011 07:16:29
Usually ships in 24 hours



Kidde 900-0113-02 Carbon Monoxide and Explosive Gas AlarmKidde 900-0113-02 Carbon Monoxide and Explosive Gas Alarm Features:; Protection from two threats, advanced alarm detects both carbon monoxide and explosive gas; AC plug with hide-a-way cord, allows direct or remote plug in; Digital readout of CO level; Continuous read of measured CO values from 30 to 999 PPM; Loud 85 decibel alarm, alerts you if CO or explosive gas levels become dangerous; Sleek design fits conveniently into any standard wall outlet; 9 volt battery included

Shop Snow Scoop Shovel

Thursday, October 27, 2011

Carbon Monoxide Alarm Maintenance, CO Alarm Testing

!±8± Carbon Monoxide Alarm Maintenance, CO Alarm Testing

Carbon monoxide alarm maintenance doesn't require any special skills from you. However, just like the smoke alarm maintenance it is something that should become a routine for you. Those few minutes dedicated to CO alarm maintenance and testing might be a difference between life and death.

Between 1999 and 2004, Carbon Monoxide poisoning contributed to 16,447 deaths in the United States... just a few minutes of your time.

If your house has been equipped with a security / burglar alarm - contact your service provider and let them know about testing procedures. CO alarms / detectors might be a part of the system. While testing the alarm, you may want to cover the siren opening with your fingers - properly functioning CO alarm will be very loud.

Test your Carbon Monoxide alarm once a week by pressing the Test/Reset button - simple, isn't it...

Depending on the design and manufacturer, the response of the CO alarm may be different, usually you should hear one short beep followed by a few seconds of silence, and a few additional beeps. This might be in addition to a blinking light, strobe like effect, or voice warning announcement.

1. Start from examining CO alarm location, it's as important as regular maintenance and testing. If the alarm has been installed improperly, in a wrong spot, it might not respond to an elevated carbon monoxide level as soon as it supposed to, or not respond at all.

2. Check the manufacturer date on you carbon monoxide alarm (there' should be a label attached to the back wall of the device) and contact its manufacturer (the easiest way would be to check their website) to determine the life span of this particular model.

Carbon Monoxide alarms have a limited lifetime, the average is around five years, but some might have as little as 2 year warranty, while others 6-7 years. Replace with a new device immediately if you confirm that its warranty has already expired.

3.Once a month vacuum your CO alarm(s) cover to remove accumulated dust. The soft brush attachment from your vacuum cleaner is the best for this purpose. If your carbon monoxide alarm is a plug-in or hard wired type - unplug / disconnect the alarm from the electrical power supply before vacuuming.

4. Always instruct children never to touch, unplug or otherwise interfere with the carbon monoxide alarm. Educate children of the dangers of CO poisoning.

5. Never use any detergents or solvents for CO alarm cleaning purposes. Chemicals can temporarily contaminate the sensor or cause permanent damage to this life saving device.

6. Never use air fresheners, spray paint, hair spray, or any other aerosols in the alarm area.

7. Do not paint the carbon monoxide alarm enclosure. Paint will seal the vents / screens protecting the sensor and interfere with its proper operation.

8. Believe it or not, but mounting the CO alarm directly above or near a diaper pail can cause faulty readings on the digital display (high amounts of methane gas).

9. Before you begin:

staining or stripping wood floors furniture painting wall-papering using aerosols or adhesives

10. Remove the CO alarm from the location you'll be performing this work in order to prevent possible damage or contamination of its sensor. You may also cover the unit with a plastic bag for the duration of the project - remember to remove the plastic and / or reinstall the CO alarm as soon as the work has been completed and area well ventilated.

Do Not Use Rechargeable Batteries in Carbon Monoxide alarms. Only alkaline type batteries should be used. Replace the batteries as soon as the unit starts chirping an audible low battery alarm, and blinking warning lights - don't just remove the old batteries - REPLACE THEM as soon as possible!

High levels of the substances listed below can affect the carbon monoxide alarm sensor. Their presence could result in temporary readings on the digital display that are actually not carbon monoxide readings:

Methane, propane, iso-butane, ethylene, ethanol, alcohol, iso-propanol, benzene, toluene, ethyl acetate, hydrogen, hydrogen sulfide, sulfur dioxides, most aerosol sprays, alcohol based products, paints, thinners, solvents, adhesives, hair sprays, after shaves, perfumes, auto exhaust (cold start) and some cleaning agents.

Two of the major CO alarm manufacturers and links to pages where you can locate manuals (please report to me if any of the links are broken);

Kidde Carbon Monoxide Alarms

First Alert Detectors

Never ignore an alarming Carbon Monoxide alarm! It is warning you of a potentially deadly hazard.

Go ahead, start your Carbon Monoxide maintenance and testing right now!


Carbon Monoxide Alarm Maintenance, CO Alarm Testing

Clicker Chamberlain Discount